CONDUCTIVITY CELLS

401Cxx0I0Y0x

Cells for measuring conductivity with hollow cylindrical body, in PVDF, and graphite electrodes. The cell constants available are K = 0.1 cm and K = 0.01 cm and the measuring ranges are 0¸200 mS and 0¸2000 mS. All 401C cells are supplied complete with Pt100 integral temperature sensor (other on request) for the thermocompensation of the measurement. The 401C through cells have ¼ ”F threaded process connections and can be installed directly on closed pipes. The typical applications of these cells are in chemical processes, in concentration measurements, in the pharmaceutical industries, in the food and beverage industry.

Data sheet

401A3x0D0Y0A

Cells for measuring conductivity with hollow cylindrical body, in AISI 316 stainless steel, and annular electrodes in graphite. The cell constant available is K = 1 cm and the measuring range is 0¸100 mS. All 401A cells are supplied complete with Pt100 integral temperature sensor (other on request) for the thermocompensation of the measurement. The 401A through cells have 3/4 ”GAS M threaded connections to the process (others on request) and can be installed directly on a closed pipe. The probe body mounts a waterproof connector for cable; only on request it is possible to have a junction box containing the terminals for the connection cable to the transmitter, with cable exit from steel cable gland. The typical applications of these cells are in chemical processes, in concentration measurements, in concentration measurements, in the pharmaceutical industries, in the food and beverage industry, in thermoelectric power plants.

Data sheet

401Exx0F0Y0A

Group of cells for the measurement of conductivity with body in PSU and glass and Platinum black platinum electrodes, suitable for industrial applications, can be installed directly in pipes and tanks. These cells can work up to 80 ° C and 5 bar (at room temperature), include the integral Pt100 temperature sensor for the thermocompensation of the measurement and the indication of the temperature. They are available with different cell constants. The typical uses of these cells are in boiler feed water, in thermal power plants, in water treatment plants, in osmosis plants.

Data sheet

401F7x0F0Y0A

Cells for measuring conductivity with body in PSU and glass and annular electrodes in platinum black platinum, suitable for industrial applications, can be installed directly into pipes and tanks. These cells can work up to 80 ° C and 5 bar (at room temperature), include the integral temperature sensor for the thermocompensation of the measurement and the indication of the temperature. The electrodes are 3, annular, in platinum platinum; thanks to the geometry of this cell, the cell constant K = 1 cm covers with very linearity a very large measuring range (0¸100000 mS). The typical uses of these cells are in boiler feed water, in thermoelectric power plants, in water treatment plants, in osmosis plants, in food systems, in the pharmaceutical industry, in chemical processes.

Data sheet

401Dxx0F0Y0A

Group of cells for measuring conductivity with body in AISI 316 and PSU and electrodes in AISI 316, suitable for industrial applications, can be installed directly in pipes and tanks. These cells can work up to 120 ° C and 6 bar (12 bar at room temperature), include the integral temperature sensor for the thermocompensation of the measurement and the indication of the temperature. They are available with different cell constants. The typical uses of these cells are in boiler feed water, in thermoelectric power plants, in food plants, in water treatment plants, in ultra-pure waters for semiconductors, in osmosis plants, in industries pharmaceuticals, in drinking water plants.

Data sheet

401Uxxxx0x0A

Group of cells for measuring conductivity with PSU, PVDF or PEEK body and graphite electrodes, suitable for industrial applications, can be installed directly in pipes and tanks. These cells can work up to 120 ° C and 2 bar (6 bar at room temperature), include the integral temperature sensor for the thermocompensation of the measurement and the indication of the temperature. They are available with different cell constants. With cell constant K = 0.1 cm they are a valid alternative to inductive principle conductivity cells, especially where there are space problems. The typical uses of these cells are in boiler feed water, in thermoelectric power plants, in food plants, in water treatment plants, in osmosis plants, in the pharmaceutical industries, in drinking water plants.

Data sheet

401Hxx0F0Y0A

Group of cells for measuring conductivity with body in AISI 316 and electrodes in AISI 316, suitable for industrial applications, can be installed directly in pipes and tanks. These cells can work up to 130 ° C and 16 bar. All cells include the integral temperature sensor for the thermocompensation of the measurement and the indication of the temperature. They are available with different cell constants. The typical uses of these cells are in boiler feed water, thermoelectric power plants, food plants, water treatment plants, ultrapure waters for semiconductors, in osmosis plants and in the pharmaceutical industries.

Data sheet

401Q0xxx0xxA

Toroidal cells for measuring conductivity, with PVC or PEEK body (other materials on request). The cells can be installed in a pipe or immersion using the appropriate accessories. In pipes of too small diameter for the direct installation of the 401Q cell, it is possible to provide a detachment and install the 401Q conductivity sensor in flow cell. They are also suitable for conductivity measurements in concentrated and / or aggressive solutions. Cells suitable for industrial applications, can be installed directly in pipes and tanks. They can work up to 50 ° C and 5 bar, (150 ° C for PEEK cells) include the integral temperature sensor for the thermocompensation of the measurement and the indication of the temperature. The typical uses of these cells are in solutions with high conductivity.

Data sheet

401Lxx0x0xx0A

Group of cells for measuring conductivity with glass body and platinum platinum electrodes. The sensors are available with cell constants K = 0.01 cm, K = 0.1 cm and K = 1 cm, therefore cover a very wide range of conductivity, from 0 to 2000 mS. All cells can be supplied complete with integral Pt100 temperature sensor (other on request) for the thermocompensation of the measurement. These cells are suitable for all normal laboratory uses; they can also be installed inside immersion probes, flow cells and some of the probes for direct in-line installation and in closed tanks, they can therefore also be used for industrial applications. The typical fields of use of these cells are therefore numerous:
industrial processes, drinking water plants, laboratories.

Data sheet

401M7x0x0xxA

Cell for measuring conductivity with glass body and 3 annular electrodes in platinum platinum. The cell constant K = 1 cm and the geometry of the electrodes allow this cell to cover with very linearity a very large measuring range, from 0 to 200 mS. The 401M cell can be supplied complete with integral Pt100 temperature sensor (or other on request) for the thermocompensation of the measurement. This cell is suitable for all normal laboratory uses; it can also be installed inside immersion probes, flow cells and some of the probes for direct in-line installation and in closed tanks, it can therefore also be used for industrial applications. The typical fields of use of these cells are therefore numerous: industrial processes, drinking water plants, laboratories.

Data sheet

401N7x0A0xxA

Cell for measuring conductivity with glass body and 3 platinum ring electrodes. The cell constant K = 1 cm and the geometry of the electrodes allow this cell to cover with very linearity a very large measuring range, from 0 to 20 mS. The electrode protection bell is easily removable for cleaning the electrodes, which being made of non-platinum platinum, can also be cleaned with mechanical systems. The 401N cell can be supplied complete with an integral temperature sensor for the thermocompensation of the measurement. This cell has been designed for use in the laboratory on particularly dirty liquids (e.g. paint measurements).

Data sheet

401J

Cells for measuring conductivity with PTFE body and graphite electrodes. The cell constant is K = 0.6 cm, corresponding to a measuring range of 0 ÷ 100 mS. All cells can be supplied complete with integral Pt100 temperature sensor (other on request) for the thermocompensation of the measurement. These cells are suitable for all normal industrial and laboratory uses. They can be installed inside immersion probes, flow cells and some of the probes for direct installation in line and in closed tanks, they are therefore usable for many industrial applications. The typical fields of use of these cells are numerous: industrial processes, drinking water plants, laboratories.

Data sheet

401Pxxxx0xxA

Group of cells for measuring conductivity with plastic body and platinum platinum electrodes. The sensors are available with cell constants K = 0.1 cm and K = 1 cm, therefore they cover a very wide range of conductivity, from 0 to 500 mS. All cells can be supplied complete with integral Pt100 temperature sensor (other on request) for the thermocompensation of the measurement. These cells are suitable for all normal laboratory uses; they are also particularly suitable for use with portable conductivity meters. The typical fields of use of these cells are therefore laboratories and field analyzes with portable instruments.

Data sheet

401V7xxx0xxA

Conductivity measuring cell with plastic body and 3 platinum platinum ring electrodes. The cell constant K = 1 cm and the geometry of the electrodes allow this cell to cover with very linearity a very large measuring range, from 0 to 100 mS. The 401V cell can be supplied complete with integral Pt100 temperature sensor (or other on request) for the thermocompensation of the measurement. This cell is suitable for all normal laboratory uses; it can also be installed inside immersion probes, flow cells and some of the probes for direct in-line installation and in closed tanks, it can therefore also be used for industrial applications. The typical fields of use of these cells are therefore numerous: industrial processes, drinking water plants, laboratories.

Data sheet

401AC5x8x0xxA

Group of cells for measuring conductivity with body in AISI 316 stainless steel and electrodes in AISI 316 steel, internal platinized electrode. The sensors are available with cell constant K = 10 cm, conductivity range, from 0 to 2000 uS. All cells can be supplied complete with integral Pt100 temperature sensor (other on request) for the thermocompensation of the measurement. These cells are suitable for all normal laboratory uses; they can also be installed inside immersion probes, flow cells and some of the probes for direct in-line installation and in closed tanks, they can therefore also be used for industrial applications. The typical fields of use of these cells are therefore numerous: industrial processes, drinking water plants, laboratories.

Data sheet

401AA e 401AB

Cells for measuring conductivity with body in glass filled PP (PP 30% GF) (optionally in PTFE or PVDF), electrodes in graphite (401AA) or stainless steel (401AB) and protective bell. The sensors are available with cell constants K = 1 cm, K = 5 cm, K = 10 cm, therefore they cover a very wide range of conductivity, from 0 to 50000 mS. All cells can be supplied complete with integral Pt100 temperature sensor (or other on request) for the thermocompensation of the measurement. These cells are extremely simple but very functional, and are threaded in the upper part to be installed in the Mod.SI0AA immersion probe. The typical fields of use of these cells are therefore numerous: industrial processes, drinking water plants, waste water treatment plants.

Data sheet

401R e 401T

Group of cells for measuring conductivity with loaded PP body glass (PP 30% GF) (optionally in PTFE or PVDF) and electrodes in graphite or stainless steel and protective bell. The sensors are available with cell constants K = 1 cm, K = 5 cm, K = 10 cm, therefore they cover a very wide range of conductivity, from 0 to 50000 mS. All the cells can be supplied complete with integral Pt100 temperature sensor (or other on request) for the thermocompensation of the measurement. These cells are extremely simple but very functional, and are suitable for measuring in closed tanks and pipes, even pressurized (up to 10 bar at room temperature). They are available with 1/2 ”G M threaded connection and thanks to the shape of their body they can be screwed by hand directly onto the pipe. The typical fields of use of these cells are therefore numerous: industrial processes, drinking water plants, treatment plants waste water, softeners, boiler feed water.

Data sheet

401AD

Group of cells for the measurement of conductivity with body in glass or in polycarbonate, with 4 platinum electrodes on ceramic support. Cell constant K = 0.7 cm-1 corresponding to 1.43 cm); these 4 electrode cells cover with very linearity a very wide conductivity range: 0-500 mS, with excellent sensitivity even at the lowest conductivity, of the uS order. All cells are complete with integral Pt1000 temperature sensor for the thermocompensation of the measure. These cells are suitable for all normal laboratory uses and can also work with very small samples, of about 1.5 ml. The 401AD cells can also be installed inside the immersion probes, the flow cells and some of the probes for direct installation in line and in closed tanks, they can therefore also be used for industrial applications. The typical fields of use of these cells are therefore numerous: processes industrial, drinking water plants, laboratories.

Data sheet

401Ixxxx0B0A e 401Gxxxx0B0A

Group of cells for the measurement of conductivity with body in PP filled with glass and electrodes in steel (401I) or in graphite (401G). The sensors are available with cell constants K = 1 cm, K = 5 cm, K = 10 cm, therefore they cover a very wide range of conductivity, from 0 to 5000 mS. All cells can be supplied complete with integral Pt100 temperature sensor (or other on request) for the thermocompensation of the measurement. These cells are extremely simple but very functional, and are suitable for measuring in closed tanks and pipes, even pressurized (up to 5 bar). They are available with different threaded connections to the process (3/8 ", 1/2" and 3/4 "G) and thanks to the shape of their body they can be screwed directly onto the pipe. The typical fields of use of these cells are therefore numerous: industrial processes, drinking water plants, waste water treatment plants, water softeners, boiler feed water.

Data sheet

401W3xxD0B0A e 401Y3xxB0B0A

Group of cells for measuring conductivity with loaded PP body glass (PP 30% GF) and graphite electrodes and removable protection bell (401W) or predisposition for protection bell (401Y). The sensors are available with cell constants K = 1 cm, therefore they cover a very wide range of conductivity, from 0 to 40000 mS. All the cells can be supplied complete with integral Pt100 temperature sensor (or other on request) for the thermocompensation of the measurement. These cells are extremely simple but very functional, and are suitable for measuring in closed tanks and pipes, even pressurized (up to 5 bar). They are available with different threaded connections to the process (3/8 ”G for the bell in the 401Y, 3/4” G for the 401W) and thanks to the shape of their body they can be screwed directly onto the pipe. The typical fields of use of these cells are therefore numerous: industrial processes, drinking water plants, waste water treatment plants, water softeners, boiler feed water.

Data sheet